Résumé du contenu

Page 1 - Bench Scales

Installation / Operator /Service ManualBench Scales© 2005-2010 by Fairbanks Scales Inc.All rights reserved50777Revision 6 -- 07/10

Page 2 - Amendment Record

07/10 10 50777 - Rev. 66. Press the [AutoTare] key to go to the division size mode. d=0.01Press the [ON/F] key to select the appropriate division siz

Page 3 - Table of Contents

07/10 11 50777 - Rev. 6A. Function keysa. Turns instrument On.b. Function key. Used for toggle switch between display weight, check-weigh or total ac

Page 4 - B. Specifications

07/10 12 50777 - Rev. 6B. Operation1. Taring All models have taring capabilities up to their total weight capacity. To weigh a sample inits containe

Page 5 - 3. Approvals

07/10 13 50777 - Rev. 6A. Error message(s)Symptom Cause SolutionOver load :* Weighing range exceed > Unload scale or reduce preloadUnder load :*

Page 6 - Section 2: Installation

07/10 14 50777 - Rev. 6A. Replacement Parts ListItem P/N Description1 24157 AC/DC Adapter 120VAC - 9Vdc @ 500 mA2 27391 Battery3 26205 Aluminum Load C

Page 7 - F. Installation

07/10 2 50777 - Rev. 6Amendment Record50777Manufactured by Fairbanks Scales Inc.821 LocustKansas City, Missouri 64106Issue 1 01/05 New ProductIssue 2

Page 8 - Section 3: Programming

07/10 3 50777 - Rev. 6Table of ContentsSection 1: General InformationA. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 4B. Speci

Page 9 - Section 4: Calibration

07/10 4 50777 - Rev. 6A. IntroductionThe Fairbanks Series II bench scales are high-accuracy, portable scales suited for bothcomercial and non-commerci

Page 10 - 07/10 10 50777 - Rev. 6

07/10 5 50777 - Rev. 62. EnvironmentalPower Supply AC/ DC adapter 110-120VAC - 9Vdc @ 500 mA,Built-in 6Vdc rechargeable lead-acid battery Up to 20hrs

Page 11

07/10 6 50777 - Rev. 6A. General Service PolicyIt is the customer / operator's responsibility to ensure the equipment provided by Fairbanksis ope

Page 12 - B. Operation

07/10 7 50777 - Rev. 6D. Instrument Location1. The Instrument should be positioned away from direct sunlight. 2. Avoid areas which have extreme varia

Page 13 - A. Error message(s)

07/10 8 50777 - Rev. 6A. Function Keys= [AutoTare] = EnterB. ProgramPress and hold any key while powering ON. The display will show CAL. Press the

Page 14 - Section 7: Parts

07/10 9 50777 - Rev. 6A. Function Keys= SelectB. Calibration Procedure1. Remove the jumper JP3 to calibrate the scale. 2. Press and hold any key whil